Cisco CW9800L 概述(硬件平台)
Cisco CW9800L 概述(硬件平台)
https://www.cisco.com/c/en/us/td/docs/wireless/controller/9800/cw9800-l/installation-guide/b-wlc-ig-cw9800l/overview.html?f_link_type=f_linkinlinenote&flow_extra=eyJpbmxpbmVfZGlzcGxheV9wb3NpdGlvbiI6MCwiZG9jX3Bvc2l0aW9uIjowLCJkb2NfaWQiOiI2NGQzYzE3MGQwMjdkMTcxLTRiYTU5MjA0NzhmZGRhYTkifQ%3D%3D
The Cisco CW9800L is a versatile hardware platform that can operate as one of two operation modes:Cisco CW9800L是一款多功能硬件平台,可运行于以下两种工作模式之一:
Wireless Controller: Functions as a next-generation, low-scale wireless controller that provides a significant boost in performance and features versus the previous model. In this mode, the CW9800L controller supports up to 10 Gbps throughput, 500 APs, and 10,000 clients, and runs Cisco IOS XE Wireless Controller firmware.无线控制器:作为一款新一代、低规模的无线控制器,与上一代产品相比,在性能和功能方面均实现了显著提升。在此模式下,CW9800L 控制器可支持高达 10 Gbps 的吞吐量、500 个 AP 以及 10,000 个客户端,并运行 Cisco IOS XE 无线控制器固件。
Campus Gateway: Operates as a Cloud-managed solution for centralized wireless deployments in small campuses. In this mode, the CW9800L controller supports up to 10 Gbps throughput, 500 APs, and 10,000 clients, and runs Cisco IOS XE Wireless Controller firmware, running Cisco IOS XE Campus Gateway firmware.园区网关:作为云管理解决方案,适用于小型园区的集中式无线部署。在此模式下,CW9800L控制器支持高达10 Gbps的吞吐量、500个AP以及1万个客户端,并运行Cisco IOS XE无线控制器固件,同时搭载Cisco IOS XE园区网关固件。
The hardware specifications are identical between the two personas; the operational differences are determined by the software and configuration.两种角色的硬件规格完全相同;其运行差异由软件及配置决定。
When deployed as a Wireless Controller, the CW9800L is ideal for on-prem managed wireless for small-to-medium sized campus deployments or medium-to-large remote sites or branch deployments. A single CW9800L can be installed in a standalone deployment, or two CW9800L units can be deployed for high availability.作为无线控制器部署时,CW9800L 非常适用于小型至中型园区的本地化无线网络管理,或中型至大型的远程站点及分支机构部署。单台 CW9800L 可用于独立部署,也可通过部署两台 CW9800L 实现高可用性。
For more information about features and benefits, see the Cisco CW9800L Wireless Controller Data Sheet.有关功能与优势的更多信息,请参阅思科 CW9800L 无线控制器产品规格说明书.
When deployed as Campus Gateway, the CW9800L targets cloud-managed, centralized wireless deployments for small-to-medium sized campus deployments or medium-to-large sized remote sites or branch deployments. A single CW9800L can be installed in a standalone deployment, or two CW9800L units can be deployed for high availability.作为校园网关部署时,CW9800L 适用于面向中小型校园网络或中大型远程站点及分支机构的云管理型集中式无线部署。单台 CW9800L 可用于独立部署,也可通过部署两台 CW9800L 实现高可用性。
For more information about the features and benefits of the Campus Gateway operation, see the Cisco Campus Gateway Data Sheet有关校园网关运行特性和优势的更多信息,请参阅思科校园网关数据手册

Summary of Cisco CW9800L Hardware Platform featuresCisco CW9800L 硬件平台功能概览
Feature功能 | Description描述 | ||
|---|---|---|---|
Chassis Height机箱高度 | One rack-unit (1RU)1个机架单位(1RU) | ||
Throughput吞吐量 | Up to 10 Gbps最高可达10 Gbps | ||
Number of APs supported支持的AP数量 | 500 | ||
Number of clients supported支持的客户端数量 | 10,000 | ||
Memory Options内存选项 | Bulk Flash: 32GB on-board pSLC eMMC (with optional eUSB support)批量闪存:32GB板载pSLC eMMC(可选eUSB支持) | ||
Redundancy, Service Ports冗余、服务端口 | 1x 1GE Cu Service/Management port1个1GE铜缆服务/管理端口 | ||
Data Ports数据端口 | 1x 1G/10G Fiber (SFP+)1个1G/10G光纤接口(SFP+) | ||
Storage Temperature存储温度 | –13° F to 158° F (–25° C to 70° C)–13°F 至 158°F(–25°C 至 70°C) | ||
Operating Temperature工作温度 | 0° C to 40° C standard, 0° C to 50° C short-term (sea level)0° C至40° C为标准工作温度,0° C至50° C为短期工作温度(海平面)
| ||
Storage Humidity存储湿度 | 0% to 95% RH non-condensing0%至95%相对湿度,无冷凝 | ||
Operating Humidity工作湿度 | 5% to 90% RH non-condensing5%至90%相对湿度,无冷凝 | ||
Operational Altitude工作海拔 | 0 to 10,000 ft (3048m) at 30° C0至10,000英尺(3048米),在30°C时 | ||
Power Adapter电源适配器 | 110W single 12V output adapter (C9800-AC-110W)110W 单路 12V 输出适配器(C9800-AC-110W) |
![]() Note注意 | The CW-ACC-MEM-32G 32GB memory module is an optional component that can only be ordered alongside the Cisco CW9800L (when ordered as a Wireless Controller) and cannot be added or ordered separately afterward. If your unit includes this optional memory module and requires a Return Merchandise Authorization (RMA), it is essential to remove the CW-ACC-MEM-32G module before returning the WLC to the depot. The replacement unit you receive from the RMA depot will not contain a memory module. Cisco Technical Assistance Center (TAC) will provide guidance during this removal process.CW-ACC-MEM-32G 32GB 内存模块为可选配件,仅可在订购 Cisco CW9800L 时一并选购(作为无线控制器订购时),且后续无法单独添加或另行订购。若您的设备已配备该可选内存模块,并需申请退货授权(RMA),请务必在将 WLC 退回仓库前先拆除 CW-ACC-MEM-32G 模块。您从RMA仓库收到的替换设备将不包含内存模块。思科技术支持中心(TAC)将在此次拆卸过程中提供指导。 |
Platform Components平台组件
Cisco CW9800L front panel思科CW9800L前面板

Table 2. Cisco CW9800L front panel components
表2.Cisco CW9800L 前面板组件
1 | Service Port (SP) (RJ-45) for out-of-band management (for WLC operation) and accessing the local status page (for Campus Gateway Operation)用于带外管理(用于无线控制器运行)以及访问本地状态页面(用于园区网关运行)的业务端口(SP)(RJ-45) | ||||
2 | Redundancy Port (RP) (RJ-45)冗余端口(RP)(RJ-45)
| ||||
3 | CPU console port, which is an RJ-45 RS-232 and micro-B USB serial console port. The default serial port settings are 9600, N, 8, 1. The boot-loader supports baud rates of 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. A default baud-rate recovery mechanism is not available; however, the bootloader ensures that the stored baud rate setting matches one of the allowed values before setting the baud rate. If a nonstandard value is detected, the baud rate will default to 9600.CPU 控制台端口,为 RJ-45 RS-232 与 micro-B USB 串行控制台端口。默认串口配置为 9600, N, 8, 1。引导程序支持的波特率包括 1200、2400、4800、9600、19200、38400、57600 和 115200。默认的波特率恢复机制不可用;然而,引导程序会在设置波特率之前确保存储的波特率设置与允许值之一相匹配。如果检测到非标准值,波特率将默认为9600。 Micro-B USB serial connection takes precedence over RJ-45 when both connections are made.当Micro-B USB串口连接与RJ-45网线同时接入时,Micro-B USB串口连接优先。
| ||||
4 | CPU console port, which is an RJ-45 RS-232 and micro-B USB serial console port. The default serial port settings are 9600, N, 8, 1. The boot-loader supports baud rates of 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. A default baud-rate recovery mechanism is not available; however, the bootloader ensures that the stored baud rate setting matches one of the allowed values before setting the baud rate. If a nonstandard value is detected, the baud rate will default to 9600.CPU 控制台端口,为 RJ-45 RS-232 与 micro-B USB 串行控制台端口。默认串口配置为 9600, N, 8, 1。引导程序支持的波特率包括 1200、2400、4800、9600、19200、38400、57600 和 115200。默认的波特率恢复机制不可用;然而,引导程序会在设置波特率之前确保存储的波特率设置与允许值之一相匹配。如果检测到非标准值,波特率将默认为9600。 Micro-B USB serial connection takes precedence over RJ-45 when both connections are made.当Micro-B USB串口连接与RJ-45网线同时接入时,Micro-B USB串口连接优先。
| ||||
5 | Type C 3.0 USB port used to perform software updates in addition to already available transfer mode, namely HTTP, TFTP, FTP, and SFTP.Type C 3.0 USB端口除支持现有的HTTP、TFTP、FTP和SFTP等传输模式外,还可用于执行软件更新。
| ||||
6 | 1x1/10G SFP+ ports. This port supports speeds of 1G and 10G.1个1x10G SFP+端口。该端口支持1G和10G速率。 | ||||
7 | Reset button重置按钮
| ||||
8 | System LED that displays power-up and boot status.用于显示上电及启动状态的系统指示灯。 | ||||
9 | Alarm LED indicates alarm staus or error states. The status or error is posted on the console screen (for wireless controller operation only).报警LED指示报警状态或错误状态。该状态或错误信息会显示在控制台屏幕上(仅适用于无线控制器操作)。 | ||||
10 | High Availability LED that indicates status of High Availability link (for wireless controller operation only).高可用性指示灯,用于显示高可用性链路的状态(仅适用于无线控制器运行)。 | ||||
11 | RFID stores identification information about the unit that can be accessed with a reader (for wireless controller operation only).RFID 存储有关设备的识别信息,可通过读卡器进行访问(仅用于无线控制器操作)。 |
Front panel LEDs: definitions of states
前面板LED指示灯:状态说明
Table 3. System LED indicators (Wireless Controller operation)
表3.系统LED指示灯(无线控制器运行状态)

Table 4. System LED indicators (Campus Gateway operation)
表4.系统LED指示灯(校园网关运行状态)
Color颜色 | Description描述 |
|---|---|
Rainbow彩虹色 | The device is initializing and trying to connect to the internet and Meraki Cloud设备正在初始化,并尝试连接至互联网和Meraki云 |
Orange橙色 | The device cannot find an uplink设备无法找到上行链路 |
Flashing White闪烁白色 | The device is updating to the latest firmware设备正在更新至最新固件 |
| White白色 | The device is online and fully operational设备已上线且运行正常 |
| Red红色 | The device is in an alarm state due to a problem with the fan, power supply, or storage由于风扇、电源或存储设备出现故障,设备处于报警状态 |
Table 5. Alarm LED indicators
表5.报警LED指示灯

Table 6. High availability LED indicators (Wireless Controller operation)
表6.高可用性LED指示灯(无线控制器运行状态)

Table 7. SFP LED indicators (Wireless Controller and Campus Gateway operation)
表7。SFP LED 指示灯(无线控制器与园区网关运行状态)
Color颜色 | Description描述 |
|---|---|
Solid green绿色常亮 | Indicates the signal detected and enabled by software表示软件检测并启用的信号 |
Solid amber固体琥珀色 | Indicates the loss of signal表示信号丢失 |
Off熄灭 | Not configured and enabled by software未配置且未被软件启用 |
The Cisco CW9800L hardware platform has an external power adapter.
Cisco CW9800L 硬件平台配备外置电源适配器。
For Wireless Controller operation, the Alarm Bell LED is illuminated red, if the 10-G uplink ports are not connected to the switch. This does not mean a system or hardware failure. When the interfaces are disabled in the controller, the red light remains off even when the controller is not connected.
在无线控制器运行时,如果10-G上行端口未连接至交换机,报警铃LED指示灯将呈红色点亮。这并不意味着系统或硬件出现故障。当控制器中的接口被禁用时,即使控制器未连接,该指示灯仍会保持熄灭状态。
For complete Campus Gateway operation, onboarding, and troubleshooting information, please refer to the Meraki documentation at https://documentation.meraki.com.
有关 Campus Gateway 的完整操作、上线及故障排除信息,请参阅 Meraki 文档,网址为
https://documentation.meraki.com.CW9800L rear panelCW9800L背面
Figure 3. Cisco CW9800L rear panel view
图3.思科CW9800L背面视图

Table 9. Cisco CW9800L rear panel components
表9.Cisco CW9800L 后面板组件
1 | Attachment slot for Kensington style cable lock.用于 Kensington 式电缆锁的固定槽。 |
2 | Connection point for external 110W, single output 12VDC power adapter (C9800-AC-110W) or optional redundant power supply (CW9800L-RPS=).用于外接110W、单路输出12VDC电源适配器(C9800-AC-110W)或可选冗余电源(CW9800L-RPS=)的连接端口。 |
2、本资源基本为原创,部分来源其他付费资源平台或互联网收集,如有侵权请联系及时处理。
3、本站大部分文章的截图来源实验测试环境,请不要在生产环境中随意模仿,以免带来灾难性后果。
转载请保留出处: www.zh-cjh.com珠海陈坚浩博客 » Cisco CW9800L 概述(硬件平台)
作者: cjh
| 手机扫一扫,手机上查看此文章: |

一切源于价值!